Freescale Semiconductor /MKV56F24 /PWM1 /DTSRCSEL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as DTSRCSEL

15 1211 87 43 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (00)SM0SEL45 0 (00)SM0SEL23 0 (00)SM1SEL45 0 (00)SM1SEL23 0 (00)SM2SEL45 0 (00)SM2SEL23 0 (00)SM3SEL45 0 (00)SM3SEL23

SM0SEL23=00, SM1SEL23=00, SM0SEL45=00, SM3SEL23=00, SM2SEL45=00, SM3SEL45=00, SM1SEL45=00, SM2SEL23=00

Description

PWM Source Select Register

Fields

SM0SEL45

Submodule 0 PWM45 Control Select

0 (00): Generated SM0PWM45 signal is used by the deadtime logic.

1 (01): Inverted generated SM0PWM45 signal is used by the deadtime logic.

2 (10): SWCOUT[SM0OUT45] is used by the deadtime logic.

3 (11): PWMx_EXTB0 signal is used by the deadtime logic.

SM0SEL23

Submodule 0 PWM23 Control Select

0 (00): Generated SM0PWM23 signal is used by the deadtime logic.

1 (01): Inverted generated SM0PWM23 signal is used by the deadtime logic.

2 (10): SWCOUT[SM0OUT23] is used by the deadtime logic.

3 (11): PWMx_EXTA0 signal is used by the deadtime logic.

SM1SEL45

Submodule 1 PWM45 Control Select

0 (00): Generated SM1PWM45 signal is used by the deadtime logic.

1 (01): Inverted generated SM1PWM45 signal is used by the deadtime logic.

2 (10): SWCOUT[SM1OUT45] is used by the deadtime logic.

3 (11): PWMx_EXTB1 signal is used by the deadtime logic.

SM1SEL23

Submodule 1 PWM23 Control Select

0 (00): Generated SM1PWM23 signal is used by the deadtime logic.

1 (01): Inverted generated SM1PWM23 signal is used by the deadtime logic.

2 (10): SWCOUT[SM1OUT23] is used by the deadtime logic.

3 (11): PWMx_EXTA1 signal is used by the deadtime logic.

SM2SEL45

Submodule 2 PWM45 Control Select

0 (00): Generated SM2PWM45 signal is used by the deadtime logic.

1 (01): Inverted generated SM2PWM45 signal is used by the deadtime logic.

2 (10): SWCOUT[SM2OUT45] is used by the deadtime logic.

3 (11): PWMx_EXTB2 signal is used by the deadtime logic.

SM2SEL23

Submodule 2 PWM23 Control Select

0 (00): Generated SM2PWM23 signal is used by the deadtime logic.

1 (01): Inverted generated SM2PWM23 signal is used by the deadtime logic.

2 (10): SWCOUT[SM2OUT23] is used by the deadtime logic.

3 (11): PWMx_EXTA2 signal is used by the deadtime logic.

SM3SEL45

Submodule 3 PWM45 Control Select

0 (00): Generated SM3PWM45 signal is used by the deadtime logic.

1 (01): Inverted generated SM3PWM45 signal is used by the deadtime logic.

2 (10): SWCOUT[SM3OUT45] is used by the deadtime logic.

3 (11): PWMx_EXTB3 signal is used by the deadtime logic.

SM3SEL23

Submodule 3 PWM23 Control Select

0 (00): Generated SM3PWM23 signal is used by the deadtime logic.

1 (01): Inverted generated SM3PWM23 signal is used by the deadtime logic.

2 (10): SWCOUT[SM3OUT23] is used by the deadtime logic.

3 (11): PWMx_EXTA3 signal is used by the deadtime logic.